Shop the DKGB2-400-2V400AH SEALED GEL LEAD ACID BATTERY at our factory for reliable and efficient power solutions. We offer top-quality products. Order now!
1. Charging efficiency: The usage of imported low resistance raw materials and advanced process help make theinternal resistance smaller and the acceptance ability of small current charging stronger.2. High and low temperature tolerance: Wide temperature range (lead-acid:-25-50 C ,and gel:-35-60 C), suitablefor indoor and outdoor use in varies environments.3. Long cycle-life: The design life of lead acid and gel series reach to more than 15 and 18 years respectively, forthe arid is corrosion- resistant. and electrolvte is without risk of stratification by using multiple rare-earth alloy ofindependent intellectual property rights, nanoscale fumed silica imported from Germany as base materials, andelectrolyte of nanometer colloid all by independent research and development.4. Environment-friendly: Cadmium (Cd), which is poisonous and not easy to recycle, does not exist. Acid leakageof gel electrolvte will not happen. The battery operates in safety and environmental protection.5. Recovery performance: The adoption of special alloys and lead paste formulations make a low self-dischargerate, good deep discharge tolerance, and strong recover capability.
Model
Voltage
Capacity
Weight
Size
DKGB2-100
2v
100Ah
5.3kg
171*71*205*205mm
DKGB2-200
2v
200Ah
12.7kg
171*110*325*364mm
DKGB2-220
2v
220Ah
13.6kg
171*110*325*364mm
DKGB2-250
2v
250Ah
16.6kg
170*150*355*366mm
DKGB2-300
2v
300Ah
18.1kg
170*150*355*366mm
DKGB2-400
2v
400Ah
25.8kg
210*171*353*363mm
DKGB2-420
2v
420Ah
26.5kg
210*171*353*363mm
DKGB2-450
2v
450Ah
27.9kg
241*172*354*365mm
DKGB2-500
2v
500Ah
29.8kg
241*172*354*365mm
DKGB2-600
2v
600Ah
36.2kg
301*175*355*365mm
DKGB2-800
2v
800Ah
50.8kg
410*175*354*365mm
DKGB2-900
2v
900AH
55.6kg
474*175*351*365mm
DKGB2-1000
2v
1000Ah
59.4kg
474*175*351*365mm
DKGB2-1200
2v
1200Ah
59.5kg
474*175*351*365mm
DKGB2-1500
2v
1500Ah
96.8kg
400*350*348*382mm
DKGB2-1600
2v
1600Ah
101.6kg
400*350*348*382mm
DKGB2-2000
2v
2000Ah
120.8kg
490*350*345*382mm
DKGB2-2500
2v
2500Ah
147kg
710*350*345*382mm
DKGB2-3000
2v
3000Ah
185kg
710*350*345*382mm
Lead ingot raw materials
Polar plate process
Electrode welding
Assemble process
Sealing process
Filling process
Charging process
Storage and shipping
Gel battery can last for several years_ Service life of gel batteryThere are two measures for battery lifeOne is the floating charge life, that is, the service life when the maximum capacity that the battery can release is not less than 80% of the rated capacity under standard temperature and continuous floating charge conditions.The second is the number of times of 80% deep cycle charging and discharging, that is, the number of times German solar cells with full capacity can be recycled after 80% of the rated capacity is discharged. Generally, engineers and technicians only attach importance to the former and neglect the latter.80% of the times of deep cycle charging and discharging represents the actual number of times that the battery can be used. In the case of frequent power outages or low quality of mains electricity, when the actual number of times of battery use has exceeded the specified number of cycles of charging and discharging, although the actual use time has not reached the calibrated floating charge life, the battery has actually failed. If it cannot be found in time, it will bring greater potential accidents.Therefore, when selecting storage battery, we should pay attention to both life indicators, and the latter is particularly important under the condition of frequent interruption of mains power. When selecting UPS supporting German solar battery, we should consider sufficient floating charge life margin. According to relevant experience, the actual service life of the battery is usually only 50%~80% of the calibrated floating charge life. This is because the actual floating charge life of the battery is related to many factors such as standard temperature, actual ambient temperature, battery charging voltage, use and maintenance.When the actual ambient temperature is 10 ℃ higher than the standard ambient temperature, the floating charge life of the battery will be shortened by half due to the doubling of the internal chemical reaction speed. Therefore, the UPS battery room should be equipped with air conditioning equipment. In terms of temperature value, the European standard is 20 ℃, and the Chinese, Japanese and American standards are 25 ℃. If the battery with a 10 year floating charge life of 20 ℃ is converted to the 25 ℃ standard, it is only equivalent to a 7-8 year floating charge life.The nominal floating charge life of the supporting battery should be the value obtained by dividing the expected actual service life of the battery by a life factor. This life coefficient is usually determined based on relevant experience. It can be 0.8 for batteries with high reliability and 0.5 for batteries with low reliability.