Performance | Item name | Parameter | Remarks |
Battery pack | Standard capacity | 52AH | 25+2°C,0.5C,New battery state |
Rated working volt | 102.4V |
Working volt range | 86.4V~116.8V | Temperature T> 0°C, Theoretical value |
Power | 5320Wh | 25+2°C,0.5C,New battery state |
Pack size (W*D*Hmm) | 625*420*175 |
Weight | 45KG |
Self-discharging | ≤3%/month | 25°C,50%SOC |
Battery pack internal resistance | 19.2-38.4mΩ | New battery state 25°C+2°C |
Static volt difference | 30mv | 25°,30%≤SOC≤80% |
Charge and discharge parameter | Standard charge/discharge current | 25A | 25+2°C |
Max sustainable charge/discharge current | 50A | 25+2°C |
Standard charge volt | Total volt max. N*115.2V | N means stacked battery pack numbers |
Standard charge mode | According to the battery charge and discharge matrix table, (if there is no matrix table. 0.5C constant current continues to charge to the single battery maximum 3.6V/total voltage maximum N*115.2V,constant voltage charge to the current 0.05C to complete the charge). |
Absolute charging temperature (cell temperature) | 0-55℃ | In any charging mode, if the cell temperature exceeds the absolute charging temperature range, it will stop charging. |
Absolute charging volt | Single max.3.6V/ Total volt max N*115.2V | In any charging mode, if the cell temperature exceeds the absolute charging temperature range, it will stop charging |
Discharge cut-of voltage | single 2.9V/total voltage N*92.8V | Temperature T>0℃, N represents the number of stacked battery packs |
Absolunte discharging temperature | -20-55°C | In any discharge mode, when the battery temperature exceeds the absolute discharge temperature, the discharge will stop |
Low temperature capacity description | 0℃ capacity | ≥80% | The new battery state, 0℃ the current is according to the matrix table. the benchmark is the nominal capacity |
-10℃ capacity | ≥75% | The new battery state, -10℃, the current is according to the matrix table the benchmark is the nominal capacity |
-20℃ capacity | ≥70% | The new battery state, -20℃ the current is according to the matrix table the benchmark is the nominal capacity |