BATTERY | |||||
Battery Module numbers | 1 | 2 | 3 | 4 | |
Battery Energy | 5.12kWh | 10.24kWh | 15.36kWh | 20.48kWh | |
Battery Capacity | 100AH | 200AH | 300AH | 400AH | |
Weight | 80kg | 133kg | 186kg | 239kg | |
Dimension L× D× H | 600×300×540 | 600×300×840 | 600×300×1240 | 600×300×1540 | |
Battery Type | LiFePO4 | ||||
Battery Rated Voltage | 51.2V | ||||
Battery Working Voltage Range | 40.0V ~ 58.4V | ||||
Maximum Charging Current | 100A | ||||
Maximum Discharging Current | 100A | ||||
DOD | 80% | ||||
Parallel Quantity | 4 | ||||
Designed Life-span | 6000Cycles | ||||
Inver & Controller | |||||
Rated Power | 5000W | ||||
Peak Power(20ms) | 15KVA | ||||
PV (Not include PV) | Charging Mode | MPPT | |||
| Rated PV input voltage | 360VDC | |||
| MPPT tracking voltage range | 120V-450V | |||
| Max PV Input Voltage Voc (At the lowest temperature) | 500V | |||
| PV Array Maximum Power | 6000W | |||
| MPPT tracking channels (input channels) | 1 | |||
Input | DC Input Voltage Range | 42VDC-60VDC | |||
| Rated AC input voltage | 220VAC / 230VAC / 240VAC | |||
| AC Input Voltage Range | 170VAC~280VAC (UPS mode)/ 120VAC~280VAC(INV mode) | |||
| AC Input Frequency Range | 45Hz~55Hz(50Hz),55Hz~65Hz(60Hz) | |||
Output | Output efficiency(Battery/PV Mode) | 94%(Peak value) | |||
| Output Voltage(Battery/PV Mode) | 220VAC±2% / 230VAC±2% / 240VAC±2% | |||
| Output Frequency(Battery/PV Mode) | 50Hz±0.5 or 60Hz±0.5 | |||
| Output Wave(Battery/PV Mode) | Pure Sine Wave | |||
| Efficiency(AC Mode) | >99% | |||
| Output Voltage(AC Mode) | Follow input | |||
| Output Frequency(AC Mode) | Follow input | |||
| Output waveform distortion Battery/PV Mode) | ≤3%(Linear load) | |||
| No load loss(Battery Mode) | ≤1% rated power | |||
| No load loss(AC Mode) | ≤0.5% rated power(charger does not work in AC mode) | |||
Protection | Battery low voltage alarm | Battery undervoltage protection value+0.5V(Single battery voltage) | |||
| Battery low voltage protection | Factory default: 10.5V(Single battery voltage) | |||
| Battery over voltage alarm | Constant charge voltage+0.8V(Single battery voltage) | |||
| Battery over voltage protection | Factory default: 17V(Single battery voltage) | |||
| Battery over voltage recovery voltage | Battery overvoltage protection value-1V(Single battery voltage) | |||
| Overload power protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Inverter output short circuit protection | Automatic protection (battery mode), circuit breaker or insurance (AC mode) | |||
| Temperature protection | >90°C(Shut down output) | |||
Working Mode | Mains priority/Solar priority/Battery priority(Can be set) | ||||
Transfer Time | ≤10ms | ||||
Display | LCD+LED | ||||
Thermal method | Cooling fan in intelligent control | ||||
Communication(Optional) | RS485/APP(WIFI monitoring or GPRS monitoring) | ||||
Environment | Operating temperature | -10℃~40℃ | |||
| Storage temperature | -15℃~60℃ | |||
| Noise | ≤55dB | |||
| Elevation | 2000m(More than derating) | |||
| Humidity | 0%~95% (No condensation) |
DKSRT01 ALL IN ONE 48V LITHIUM BATTERY WITH INVERTER AND CONTROLLER
Get the ultimate power solution with DKSRT01 ALL IN ONE 48V Lithium Battery! Our factory ensures top quality and reliability. Shop now for efficient energy conversion.
Request a QuotePRODUCTS DETAILS
Hot Products
Contact us
Please feel free to give your inquiry in the form below We will reply you in 24 hours