DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN

DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN - High-quality factory-made product for efficient power conversion. Shop now for reliable and innovative solutions.

Request a Quote
  • DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN
  • DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN
  • DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN
  • DKWD-PURE SINGLE WAVE INVERTER WITH MPPT CONTROLLER BUILT IN

PRODUCTS DETAILS

Model DKWD

70112/24 (701)

10212/24 (102)

15224/48 (152)

20224/48 (202)

30224/48(302)

Rated Power

700W

1000W

1500W

2000W

3000W

Peak Power(20ms)

2100VA

3000VA

4500VA

6000VA

9000VA

Start Motor

0.5HP

1HP

1.5HP

2HP

3HP

Battery Voltage

12/24VDC

12/24VDC

24/48VDC

24/48VDC

24/48VDC

Max AC charging current

0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)

Built-in solar controller charging current (optional)

10A~60A(PWM or MPPT)

24/48V(PWM:10A~60A/MPPT:10A~100A)

Size(L*W*Hmm)

340x165x283

410x200x350

Packing Size(L*W*Hmm)

405x230x340(1pc) / 475x415x350(2pc)

475x265x410

N.W.(kg)

9.5(1pc)

10.5(1pc)

11.5(1pc)

17

20.5

G.W.(kg)

11(1pc)

12(1pc)

13(1pc)

19

22.5

Installation Method

Tower

Model DKWD

80248/96/192 (802)

10348/96/192 (103)

12396/192 (123)

153192 (153)

203192 (203)

Rated Power

8KW

10KW

12KW

15KW

20KW

Peak Power(20ms)

24KVA

30KVA

36KVA

45KVA

60KVA

Start Motor

5HP

7HP

7HP

10HP

12HP

Battery Voltage

48/96/192VDC

48/96V/192VDC

96/192VDC

192VDC

192VDC

Max AC charging current

0A~40A(Depending on the model,The maximum charging power is 1/4 of the rated power)

0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)

Built-in solar controller charging current (optional)

PWM:(48V:120A;96V:50A/100A;192V/384V:50A)                                                  MPPT:(48V:100A/200A;96V:50A/100A;192V/384V:50A)

50A/100A

Size(L*W*Hmm)

540x350x695

593x370x820

Packing Size(L*W*Hmm)

600*410*810

656*420*937

N.W.(kg)

66

70

77

110

116

G.W.(kg)

77

81

88

124

130

Installation Method

Tower

Input

DC Input Voltage Range

10.5-15VDC(Single battery voltage)

AC Input Voltage Range

73VAC~138VAC(110VAC) /  83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) /  155VAC~285VAC(230VAC) /  165VAC~295VAC( 240VAC) (700W~7000W) 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) /  185VAC~255VAC(220VAC) /  195VAC~265VAC(230VAC) /  205VAC~275VAC( 240VAC) (8KW~40KW)

AC Input Frequency Range

45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)

AC charging method

Three-stage (constant current, constant voltage, floating charge)

Output

Efficiency(Battery Mode)

≥85%

Output Voltage(Battery Mode)

110VAC±2%  / 120VAC±2%  / 220VAC±2%  / 230VAC±2%  / 240VAC±2%

Output Frequency(Battery Mode)

50Hz±0.5 or 60Hz±0.5

Output Wave(Battery Mode)

Pure Sine Wave

Efficiency(AC Mode)

>99%

Output Voltage(AC Mode)

Follow input

Output Frequency(AC Mode)

Tracking Automatically

Output waveform distortion (Battery Mode)

≤3%(Linear load)

No load loss(Battery Mode)

≤1% rated power

No load loss(AC Mode)

 ≤2% rated power( charger does not work in AC mode)

No load loss (Energy saving Mode)

≤10W

Battery Type (selectable)

VRLA Battery

Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)

Customize battery

Charging and discharging parameters of different types of batteries can be customized according to user requirements  (charging and discharging parameters of different types of batteries can be set through the operation panel)

Protection

Battery undervoltage alarm

Factory default: 11V(Single battery voltage)

Battery undervoltage protection

Factory default: 10.5V(Single battery voltage)

Battery overvoltage alarm

Factory default: 15V(Single battery voltage)

Battery overvoltage protection

Factory default: 17V(Single battery voltage)

Battery overvoltage recovery voltage

Factory default: 14.5V(Single battery voltage)

Overload power protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Inverter output short circuit protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Temperature protection

>90°C(Shut down output)

Alarm

A

Normal working condition, buzzer has no alarm sound

B

Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection

C

When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal

Inside Solar controller (Optional)

Charging Mode

PWM or MPPT

PV Input Voltage Range

PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system); 120V-176V(96V system);240V-352V(192V system) ;300V-400V(240V system); 480V-704V(384V system)  MPPT:  15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system); 120V-240V(96V system);240V-360V(192V system);300V-400V(240V system);480V-640V(384V system)

Max PV Input Voltage(Voc) (At the lowest temperature)

PWM:  50V(12V/24V system); 100V(48V system); 200V(96V system);400V(192V system);500V(240V system) ;750V(384V system)  MPPT: 150V(12V/24V/48V system); 300V(96V system);450V(192V system);500V(240V system) ;800V(384V system)

PV Array Maximum Power

12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)/6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A); 96V system:  5.6KW(50A)/11.2KW(100A);192V system: (PWM:11.2KW(50A)/22.4KW(100A)) / (MPPT:11.2KW(50A)/11.2*2KW(100A)); 240V system: (PWM:14KW(50A)/28KW(100A)) / (MPPT:14KW(50A)/14*2KW(100A));384V system: (PWM:22.4KW(50A)/44.8KW(100A)) / (MPPT:22.4KW(50A)/22.4*2KW(100A))

Standby loss

≤3W

Maximum conversion efficiency

>95%

Working Mode

Battery First/AC First/Saving Energy Mode

Transfer Time

≤4ms

Display

LCD

Thermal method

Cooling fan in intelligent control

Communication(Optional)

RS485/APP(WIFI monitoring or GPRS monitoring)

Environment

Operating temperature

-10℃~40℃

Storage temperature

-15℃~60℃

Noise

≤55dB

Elevation

2000m(More than derating)

Humidity

0%~95% ,No condensation

What service we offer? 1. Design service. Just let us know the features you want, such as the power rate, the applications you want to load, how many hours you need the system to work etc. We will design a reasonable solar power system for you. We will make a diagram of the system and the detailed configuration. 2. Tender Services Assist guests in preparing bid documents and technical data 3. Training service If you a new one in the energy storage business, and you need a training, you can come our company to learn or we send technicians to help you to train your stuff. 4. Mounting service& maintenance service We also offer mounting service and maintenance service with seasonable & affordable cost.5. Marketing support We give big support to the customers who agent our brand "Dking power". we send engineers and technicians to support you if necessary. we send certain percent extra parts of some of the products as replacements freely. What is the minimum and max solar power system you can produce? The minimum solar power system we produced is around 30w, such as solar street light. But normally the minimum for home use is 100w 200w 300w 500w etc. Most of people prefer 1kw 2kw 3kw 5kw 10kw etc for home use, normally it is AC110v or 220v and 230v. The max solar power system we produced is 30MW/50MWH.How is your quality? Our quality is very high,because we use very high quality materials and we make rigorous tests of the materials. And we have very strict QC system.Do you accept customized producing? Yes. just tell us what you want. We customized R&D and producing energy storage lithium batteries, low temperature lithium batteries, motive lithium batteries, off high way vehicle lithium batteries, solar power systems etc. What is the lead time? Normally 20-30 days How you guarantee your products? During the warranty period, if it is the product reason, we will send you replacement of the product. Some of the products we will send you new one with next shipping. Different products with different warranty terms. But before we sending, we need a picture or video to make sure it is the problem of our products.400KWH (192V2000AH Lifepo4 and solar energy storage system in Philippines ) 200KW PV+384V1200AH (500KWH) solar and lithium battery energy storage system in Nigeria400KW PV+384V2500AH (1000KWH) solar and lithium battery energy storage system in America.
Model DKWD

35248/96 (352)

40248/96(402)

50248/96(502)

60248/96(602)

70248/96/192(702)

Rated Power

3500W

4000W

5000W

6000W

7000W

Peak Power(20ms)

10500VA

12000VA

15000VA

18000VA

21000VA

Start Motor

3HP

3HP

4HP

4HP

5HP

Battery Voltage

48/96VDC

48/96VDC

48/96VDC

48/96VDC

48/96/192VDC

Max AC charging current

0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)

Built-in solar controller charging current (optional)

24/48V(PWM:10A~60A/MPPT:10A~100A)

48V(PWM:10A~120A/MPPT:10A~100A) /  96V(50A/100A(PWM or MPPT))

Size(L*W*Hmm)

410x200x350

491x260x490

Packing Size(L*W*Hmm)

475x265x410

545x315x550

N.W.(kg)

21.5

29

30

31.5

36

G.W.(kg)

23.5

32

33

34.5

39

Installation Method

Tower

Model DKWD

253240 (253)

303240 (303)

403384 (403)

Rated Power

25KW

30KW

40KW

Peak Power(20ms)

75KVA

90KVA

120KVA

Start Motor

15HP

15HP

20HP

Battery Voltage

240VDC

240VDC

384VDC

Max AC charging current

0A~20A(Depending on the model,The maximum charging power is 1/4 of the rated power)

Built-in solar controller charging current (optional)

50A/100A

50A/100A

Size(L*W*Hmm)

593x370x820

721x400x1002

Packing Size(L*W*Hmm)

656*420*937

775x465x1120

N.W.(kg)

123

167

192

G.W.(kg)

137

190

215

Installation Method

Tower

Input

DC Input Voltage Range

10.5-15VDC(Single battery voltage)

AC Input Voltage Range

73VAC~138VAC(110VAC) /  83VAC~148VAC(120VAC) / 145VAC~275VAC(220VAC) /  155VAC~285VAC(230VAC) /  165VAC~295VAC( 240VAC) (700W~7000W) 92VAC~128VAC(110VAC) / 102VAC~138VAC(120VAC) /  185VAC~255VAC(220VAC) /  195VAC~265VAC(230VAC) /  205VAC~275VAC( 240VAC) (8KW~40KW)

AC Input Frequency Range

45Hz~55Hz(50Hz)/ 55Hz~65Hz(60Hz)

AC charging method

Three-stage (constant current, constant voltage, floating charge)

Output

Efficiency(Battery Mode)

≥85%

Output Voltage(Battery Mode)

110VAC±2%  / 120VAC±2%  / 220VAC±2%  / 230VAC±2%  / 240VAC±2%

Output Frequency(Battery Mode)

50Hz±0.5 or 60Hz±0.5

Output Wave(Battery Mode)

Pure Sine Wave

Efficiency(AC Mode)

>99%

Output Voltage(AC Mode)

Follow input

Output Frequency(AC Mode)

Tracking Automatically

Output waveform distortion (Battery Mode)

≤3%(Linear load)

No load loss(Battery Mode)

≤1% rated power

No load loss(AC Mode)

 ≤2% rated power( charger does not work in AC mode)

No load loss (Energy saving Mode)

≤10W

Battery Type (selectable)

VRLA Battery

Charge Voltage :14.2V; Float Voltage:13.8V(Single battery voltage)

Customize battery

Charging and discharging parameters of different types of batteries can be customized according to user requirements  (charging and discharging parameters of different types of batteries can be set through the operation panel)

Protection

Battery undervoltage alarm

Factory default: 11V(Single battery voltage)

Battery undervoltage protection

Factory default: 10.5V(Single battery voltage)

Battery overvoltage alarm

Factory default: 15V(Single battery voltage)

Battery overvoltage protection

Factory default: 17V(Single battery voltage)

Battery overvoltage recovery voltage

Factory default: 14.5V(Single battery voltage)

Overload power protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Inverter output short circuit protection

Automatic protection (battery mode), circuit breaker or insurance (AC mode)

Temperature protection

>90°C(Shut down output)

Alarm

A

Normal working condition, buzzer has no alarm sound

B

Buzzer sounds 4 times per second when battery failure, voltage abnormality, overload protection

C

When the machine is turned on for the first time, the buzzer will prompt 5 when the machine is normal

Inside Solar controller (Optional)

Charging Mode

PWM or MPPT

PV Input Voltage Range

PWM: 15V-44V(12V system); 30V-44V(24V system); 60V-88V(48V system); 120V-176V(96V system);240V-352V(192V system) ;300V-400V(240V system); 480V-704V(384V system)  MPPT:  15V-120V(12V system); 30V-120V(24V system); 60V-120V(48V system); 120V-240V(96V system);240V-360V(192V system);300V-400V(240V system);480V-640V(384V system)

Max PV Input Voltage(Voc) (At the lowest temperature)

PWM:  50V(12V/24V system); 100V(48V system); 200V(96V system);400V(192V system);500V(240V system) ;750V(384V system)  MPPT: 150V(12V/24V/48V system); 300V(96V system);450V(192V system);500V(240V system) ;800V(384V system)

PV Array Maximum Power

12V system: 140W(10A)/280W(20A)/420W(30A)/560W(40A)/700W(50A)/840W(60A)/1120W(80A)/1400W(100A); 24V system: 280W(10A)/560W(20A)/840W(30A)/1120W(40A)/1400W(50A)/1680W(60A)/2240W(80A)/2800W(100A); 48V system: 560W(10A)/1120W(20A)/1680W(30A)/2240W(40A)/2800W(50A)/3360W(60A)/4480W(80A)/5600W(100A)/6720W(PWM 120A)/5.6KW&11.2KW(MPPT 100A/200A); 96V system:  5.6KW(50A)/11.2KW(100A);192V system: (PWM:11.2KW(50A)/22.4KW(100A)) / (MPPT:11.2KW(50A)/11.2*2KW(100A)); 240V system: (PWM:14KW(50A)/28KW(100A)) / (MPPT:14KW(50A)/14*2KW(100A));384V system: (PWM:22.4KW(50A)/44.8KW(100A)) / (MPPT:22.4KW(50A)/22.4*2KW(100A))

Standby loss

≤3W

Maximum conversion efficiency

>95%

Working Mode

Battery First/AC First/Saving Energy Mode

Transfer Time

≤4ms

Display

LCD

Thermal method

Cooling fan in intelligent control

Communication(Optional)

RS485/APP(WIFI monitoring or GPRS monitoring)

Environment

Operating temperature

-10℃~40℃

Storage temperature

-15℃~60℃

Noise

≤55dB

Elevation

2000m(More than derating)

Humidity

0%~95% ,No condensation

Hot Products

DKGB-1265-12V65AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB-1265-12V65AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB2-250-2V250AH SEALED GEL LEAD ACID BATTERY

DKGB2-250-2V250AH SEALED GEL LEAD ACID BATTERY

DKGB-1290-12V90AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB-1290-12V90AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKSESS 8KW OFF GRID/HYBRID ALL IN ONE SOLAR POWER SYSTEM

DKSESS 8KW OFF GRID/HYBRID ALL IN ONE SOLAR POWER SYSTEM

DKGB-12200-12V200AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB-12200-12V200AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB2-500-2V500AH SEALED GEL LEAD ACID BATTERY

DKGB2-500-2V500AH SEALED GEL LEAD ACID BATTERY

DKGB-12150-12V150AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB-12150-12V150AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB2-300-2V300AH SEALED GEL LEAD ACID BATTERY

DKGB2-300-2V300AH SEALED GEL LEAD ACID BATTERY

DKGB-12100-12V100AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DKGB-12100-12V100AH SEALED MAINTANANCE FREE GEL BATTERY SOLAR BATTERY

DK TELECOM TOWER BATTERY BASE STATION LITHIUM BATTERY

DK TELECOM TOWER BATTERY BASE STATION LITHIUM BATTERY

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours